Tape Drives on old AS/400: Difference between revisions
Jump to navigation
Jump to search
(Addition) |
(+Combination) |
||
Line 11: | Line 11: | ||
|Save/Restore/BMR<ref>''B''are ''M''etal ''R''estore, IPL from tape and restore of the entire system.</ref> | |Save/Restore/BMR<ref>''B''are ''M''etal ''R''estore, IPL from tape and restore of the entire system.</ref> | ||
|DIP-Switches set to default. | |DIP-Switches set to default. | ||
|- style="vertical-align:top; background-color:#ddffdd;" | |||
|HP DLTVS 80<ref>'''Caution!''' Protect the controller board of the drive with a piece of carton or other insulating material. The EMI prevention springs will scratch components from the board otherwise.</ref> | |||
|9406-S20/V4R4 + 2726 SCSI RAID-Controller | |||
|Save/Restore | |||
|SCSI-Error logged at IPL time.<br />Works otherwise. | |||
|-style="vertical-align:top; background-color:#ddffdd;" | |||
|HP LTO1 | |||
|9401-800/V5R2 | |||
|Save/Restore | |||
|SCSI-Error logged at IPL time.<br />Works otherwise. | |||
|- style="vertical-align:top; background-color:#ffffdd;" | |- style="vertical-align:top; background-color:#ffffdd;" | ||
|Conner CDT20004R-S | |Conner CDT20004R-S | ||
Line 16: | Line 26: | ||
|Save/Restore | |Save/Restore | ||
|DIP-Switches set to default.<br />SCSI errors are logged for every initial access.<br />Otherwise works. | |DIP-Switches set to default.<br />SCSI errors are logged for every initial access.<br />Otherwise works. | ||
|- style="vertical-align:top; background-color:#ffdddd;" | |- style="vertical-align:top; background-color:#ffdddd;" | ||
|HP DDS-1/2/3 | |HP DDS-1/2/3 |
Revision as of 08:10, 3 August 2020
The QIC drives contained in many older machines are often defective, or it's expensive to impossible to get actual tapes for these drives. Sometimes, stock tape drives can be used also. This article documents which combination of machine, OS release, and drive has been tested so far.
Drive | Server/OS | Tasks tested | Remark |
---|---|---|---|
HP DDS-1/2/3 | 9401-150/V4R5 | Save/Restore/BMR[1] | DIP-Switches set to default. |
HP DLTVS 80[2] | 9406-S20/V4R4 + 2726 SCSI RAID-Controller | Save/Restore | SCSI-Error logged at IPL time. Works otherwise. |
HP LTO1 | 9401-800/V5R2 | Save/Restore | SCSI-Error logged at IPL time. Works otherwise. |
Conner CDT20004R-S | 9401-150/V4R5 | Save/Restore | DIP-Switches set to default. SCSI errors are logged for every initial access. Otherwise works. |
HP DDS-1/2/3 | 9402-400/V4R2 | None. | DIP-Switches set to default. Drive not recognised in DST. |