Older hardware might suffer from disk device related errors more frequently. Interestingly, detailed information is hard to find. This is because system reference codes often refer to a certain piece of hardware (Feature Code) or FC and the actual error code. Because IBM over time released a multitude of disk devices, the possible combinations are plenty. This means, querying an internet search engine most likely will not turn up the desired results.

The following table lists the documented second half of SRCs[1] for the disk devices

  • 432x,
  • 660x,
  • 671x,
  • 673x.
SRC Description
102E Out of alternate sectors for disk storage[2]
3002 Addressed device failed to respond to SCSI selection
3010 Disk device returned wrong/unexpected response to IOP
3020 Storage subsystem configuration error
3029 A device replacement has occurred
3100 Tape/CD or disk bus interface error occurred
3109 IOP timed out a disk command
3110 Disk bus interface error occurred
3130 Incompatible/missing Device Licensed Internal Code
3131 Device or IOA Licensed Internal Code does not support a needed attribute and is running with degraded performance
7000 Disk sector read error
7001 Temporary disk data error
7003 Device format error
7004 Just a log entry, no further clarification provided
7050 Data compression failure
7051 Compressed device and compression IOA are not compatible
7052 Data compression warning
FFF2 Disk motor problem
FFF3 Disk media format bad
FFF4 Generic disk device problem
FFF5 Disk sector read error
FFF6 Disk device detected recoverable error
FFF7 to FFF9 Temporary disk data error
FFFA Temporary disk bus error
FFFB SCSI bus reset occurred
FFFE Temporary disk bus error